    Caractéristiques techniques
    • Nom de la marquePrestige
    • Procédé de chauffageElectrique
    la description
    Product description (*)

    Very high efficiency wall hung condensing boiler
    Dual application boiler with 62 litres domestic hot water tank
    Heat exchanger made of stainless steel with outstanding resistence to high temperature corrosion
    Premix gas burner, for natural gas or propane
    With 12 litres expansion vessel
    Intuitive user controls
    Advanced programmable options
    Internet ready, via optional gateway
    Sealed combustion chimney connection
    Hydraulic kits and control devices available in option


    Main characteristics
    Input max. (heating) (kW) : 18
    Input min. (heating) (kW) : 2,2
    Output power max. (80/60°C) (kW) : 17,5
    Efficiency (max. output) 80/60°C (%) : 97
    Peak flow at 40 °C (L/10') : 175
    Dim. - Width or Diameter (w/o conn.) (mm) : 630
    Dim. - Depth (w/o conn.) (mm) : 560
    Dim. - Height (w/o conn.) (mm) : 1000

    Design characteristics

    Concentric chimney connection Ø 60/100 mm with sampling point
    Automatic air vent valve
    Burner unit
    Stainless steel heat exchanger
    Exhaust tube
    Condensate collector
    Condensate trap
    Acoustic insulation
    Air inlet tube
    12 litre heating circuit expansion tank
    Control panel

    Technical specifications (*)
    CharacteristicsValue
    Input max. (heating) 18 kW
    Input min. (heating) 2,2 kW
    Output power max. (80/60°C) 17,5 kW
    Output power min. (60/80°C)) 2,1 kW
    Efficiency (max. output) 80/60°C 97 %
    Efficiency at 100% load (50/30°C) 106,1 %
    Efficiency at 30% load (EN677) 109 %
    CO emissions (max./min. output) 10 mg/kWh
    NOx emissions (max./min. output) 39,9 mg/kwh
    NOx class (EN483) 5
    Flue gas temperature at max.output 80/60°C 62 °C
    Mass rate of combustion products (gas) 29,56 Kg/h
    Chimney: Max.pressure drop in flue pipe 130 Pa
    Chimney: max. length of concentric flue pipe 25 m
    Chimney connection Ø 60/100 80/125 mm
    Gas flow rate G20 (max.output) 1,9 (20mbar) m³/h
    Gas flow rate G25 (max.output) 2,21 (25 mbar) m³/h
    Gas flow rate G31 (max.output) 0,74 (37 mbar) m³/h
    CO2 (max / min output) G20/G25 8,9 / 8,6 %CO2
    CO2 (max / min output) G31 10,5 / 10,2 %CO2
    Connection - gas 3/4" (M) Ø
    Capacity (primary) 16 L
    Capacity (domestic hot water) 54 L
    Capacity expansion tank(s) 12 L
    Water pressure drop boiler at Δt = 20°C 85 mbar
    Primary flow 740 L/h
    Connection - heating (F) 3/4" (M) Ø
    Max. operating temperature 90 °C
    Max.service pressure heating (primary) 3 bar
    Max.service pressure (DHW) 10 bar
    Protection X4D
    Operating voltage (50Hz) 230 V
    Electrical consumption 135 W
    Dim. - Width or Diameter (w/o conn.) 630 mm
    Dim. - Depth (w/o conn.) 560 mm
    Dim. - Height (w/o conn.) 1000 mm
    Weight (empty) 78 Kg

    Contact the seller
    Hot water Tanks and Boilers > Prestige 18 Excellence MkIII
    Hot water Tanks and Boilers  >  Prestige 18 Excellence MkIII
    View also produits catégories "Chaudières à grand volume d'eau, bouilleurs"